MD00678.DYNALIB - z/OS 1.11 Compatibility fix
Product: DYNA-LIB 2.6.0
Applies To: ALL
Fixes: ALL
Problem Description
Description: z/OS 1.11: DYNASTEP 'ADD', 'DA', 'DELETE' (steplib/alternate DD) commands are not functional.
Special Note:

Since the PTF consists of module replacements, it is in binary format, and must be uploaded to your mainframe in binary format with fixed record format and LRECL=80.

This PTF has pre-requisites MD59986 and MD00291.DYNALIB.

Install Note: 1 - Uninstall the current DynaStep environment by
running the DYNUNINT procedure
(usually S DYNUNINT).

2 - Uninstall the protected code by running DYNUNINT
again, but with the UNLOAD SVC REQUEST parameter
(usually S DYNUNINT,PARM='UNLOAD SVC REQUEST').

3 - Install the new DynaStep environment by running
the DYNINIT procedure (usually S DYNINIT).

4 - Ensure that the DYNASTEP module being executed
is at the correct level by using the 'VER'
parameter and verifying that the date/time
in the message is 09/02/09 09.02.
Problem Fix
SMP/E: Click here to download the fix MD00678.DYNALIB