MD00291.DYNALIB - Problems with authorized applications and DYNA-LIB
Product: DYNA-LIB 2.6.0
Applies To: ALL
Fixes: ALL
Problem Description
Description: User receives ABENDS206-C8 when using DYNA-LIB and IOF together, and IOF attempts to issue an MVS or JES command.
Special Note:

Since the PTF consists of module replacements, it is in binary format, and must be uploaded to your mainframe in binary format with fixed record format and LRECL=80.

This PTF has a pre-requisite MD59986

Install Note: 1 - Uninstall the current DynaStep environment by
running the DYNUNINT procedure
(usually S DYNUNINT).

2 - Uninstall the protected code by running DYNUNINT
again, but with the UNLOAD SVC REQUEST parameter
(usually S DYNUNINT,PARM='UNLOAD SVC REQUEST').

3 - Install the new DynaStep environment by running
the DYNINIT procedure (usually S DYNINIT).

4 - Ensure that the ISPEXITS module contains the new
DYNAISPF module (eyecatcher is 02/20/09 04.49).

5 - Ensure that the DYNASTEP module being executed
is at the correct level by using the 'VER'
parameter and verifying that the date/time
in the message is 08/25/09 11.29.
Problem Fix
Download Fix: Click here to download the fix MD00291.DYNALIB